Partition alignment for VMware guests
At an EMC class I took recently, the instructor claimed that in testing she had done, correctly aligning the partitions on a physical Windows server resulted in 30% performance gains. I’m not sure what, if anything the gain is for aligning the partitions in virtual disks, assuming the underlying VMFS LUNs are aligned (which by default they will be if they’re created under ESX 3+ or vSphere). That being said, this is the advice from the “Performance Best Practices for VMware vSphere 4.0″ guide: Make sure the system partitions within the guest are aligned. For further information you might want torefer to the literature from the operating system vendor regarding appropriate tools to use as well asrecommendations from the array vendor. (from http://www.vmware.com/pdf/Perf_Best_Practices_vSphere4.0.pdf) Accordingly, I have my Windows VM templates configured with aligned partitions. See http://technet.microsoft.com/en-us/library/aa995867(EXCHG.65).aspx and http://support.microsoft.com/kb/929491 for info on aligning windows partitions. This is a potentially useful tool — a powershell script to check the partition alignment of your Windows VMs. (via Scott Lowe ) I haven’t adjusted the partition alignment on my Linux VM templates yet. That’s on my To Do list, hopefully for some time in the near future. I plan to do some before and after performance testing, and I’ll post the results here when I do. -Matt
New Jersey Snowstorm
Major Disaster Declaration number 1873 declared on Feb 05, 2010
Arizona Severe Winter Storm
Emergency Declaration number 3307 declared on Jan 24, 2010
Georgia Severe Storms and Flooding
Major Disaster Declaration number 1858 declared on Sep 24, 2009
Arizona Twin Fire
Fire Management Assistance Declaration number 2840 declared on Oct 03, 2009
Pano Logic - Solutions Brochure
Frogger 13,430.. beat that!
Head upstairs and into the bar in the virtual confierence and play frogger in the bar, see if you can beatmy score of 13,430!
Puerto Rico Explosions and Fire
Emergency Declaration number 3306 declared on Oct 24, 2009
vSphere ESXi 4U1 Embedded Query
Is anyone out there running the ESXi 4U1 Embedded from Dell that includes the Dell Open Manage bits? I am having a helluva time reflashing my servers that are running ESXi 3.5 Embedded. I am getting a variation of the PSOD during the loading of the setup program. The server in question is a Dell PowerEdge 2900 with 32 GB RAM, 4 GB USB Flash for embedded ESXi and 2 RAID 5 arrays (1.6 TB & 800 GB). Anyone else running into any update issues?

